File Name: C:\Program Files\Bio-Rad\Bio-Plex Manager 5.0\users\Craig\Results\Saliva IgA Luitpold d22 061813.rbx
Analyte: IgA (63)
Acquisition Date: 18-Jun-2013, 11:42 AM
Reader Serial Number: LX10008241401
Plate ID: 
RP1 PMT (Volts): 648.60
RP1 Target: 17026
Analyte Type Well Outlier Description FI FI - Bkgd Std Dev Std Err %CV Obs Conc Exp Conc (Obs/Exp) * 100 Conc in Range Bead Count Sampling Errors
IgA (63) B A1,B1,C1,D1 0 68.5 68.5 4.18 2.09 6.11
IgA (63) S1 E1,F1 2 Standard 1 19160.5 19092 0 0 0 477.33 500 95 477.33
IgA (63) S2 G1,H1 0 Standard 2 17024.5 16956 195.16 138 1.15 277.63 250 111 277.63
IgA (63) S3 A2,B2 0 Standard 3 12901.8 12833.3 189.15 133.75 1.47 118.12 125 94 118.12
IgA (63) S4 C2,D2 0 Standard 4 9426.8 9358.3 3.89 2.75 0.04 61.01 62.5 98 61.01
IgA (63) S5 E2,F2 0 Standard 5 6474.5 6406 51.62 36.5 0.8 33.39 31.25 107 33.39
IgA (63) S6 G2,H2 0 Standard 6 3461.3 3392.8 154.5 109.25 4.46 14.95 15.63 96 14.95
IgA (63) S7 A3,B3 0 Standard 7 2014.5 1946 169.71 120 8.42 7.98 7.81 102 7.98
IgA (63) S8 C3,D3 2 Standard 8 1153.5 1085 0 0 0 3.88 3.91 99 3.88
IgA (63) X1 E3,F3 0 4661 2389.5 2321 7.07 5 0.3 9728.55 9728.55
IgA (63) X2 G3,H3 0 4331 2965 2896.5 5.66 4 0.19 12476.35 12476.35
IgA (63) X3 A4,B4 0 4326 8833 8764.5 132.23 93.5 1.5 54369.31 54369.31
IgA (63) X4 C4,D4 0 4651 7237.5 7169 4.95 3.5 0.07 39370.91 39370.91
IgA (63) X5 E4,F4 0 4653 6277.8 6209.3 272.59 192.75 4.34 31949.54 31949.54
IgA (63) X6 G4,H4 0 4654 1550.8 1482.3 3.89 2.75 0.25 5819.08 5819.08
IgA (63) X7 A5,B5 0 4655 4619.5 4551 173.24 122.5 3.75 21234.45 21234.45
IgA (63) X8 C5,D5 0 4657 1945.5 1877 47.38 33.5 2.44 7660.65 7660.65
IgA (63) X9 E5,F5 0 4658 3977.5 3909 24.75 17.5 0.62 17650.41 17650.41
IgA (63) X10 G5,H5 0 4659 13364 13295.5 19.09 13.5 0.14 129150.31 129150.31
IgA (63) X11 A6,B6 0 4660 8135.3 8066.8 369.46 261.25 4.54 47345.59 47345.59
IgA (63) X12 C6,D6 0 4662 3852.3 3783.8 14.5 10.25 0.38 16981.17 16981.17
IgA (63) X13 E6,F6 0 4663 6292.3 6223.8 73.19 51.75 1.16 32054.22 32054.22
IgA (63) X14 G6,H6 0 4665 1542.3 1473.8 8.13 5.75 0.53 5778.95 5778.95
IgA (63) X15 A7,B7 0 4666 2116 2047.5 72.12 51 3.41 8452.15 8452.15
IgA (63) X16 C7,D7 0 4667 5898.5 5830 36.77 26 0.62 29285.53 29285.53
IgA (63) X17 E7,F7 0 4669 2643.3 2574.8 22.27 15.75 0.84 10927.3 10927.3
IgA (63) X18 G7,H7 0 4670 5432.3 5363.8 94.4 66.75 1.74 26193.9 26193.9
IgA (63) X19 A8,B8 0 4671 7747.5 7679 345.78 244.5 4.46 43765.74 43765.74
IgA (63) X20 C8,D8 0 7672 4301.8 4233.3 1.77 1.25 0.04 19427.11 19427.11
Analyte Type Well Outlier Description FI FI - Bkgd Std Dev Std Err %CV Obs Conc Exp Conc (Obs/Exp) * 100 Conc in Range Bead Count Sampling Errors
IgA (63) B A1 0 72 72 100
IgA (63) B B1 0 69 69 100
IgA (63) B C1 0 62.5 62.5 100
IgA (63) B D1 0 70.5 70.5 100
IgA (63) S1 E1 1 19433.5 19365 500 100
IgA (63) S1 F1 0 19160.5 19092 477.33 500 95 477.33 100
IgA (63) S2 G1 0 17162.5 17094 286.68 250 115 286.68 100
IgA (63) S2 H1 0 16886.5 16818 268.96 250 108 268.96 100
IgA (63) S3 A2 0 12768 12699.5 115.13 125 92 115.13 100
IgA (63) S3 B2 0 13035.5 12967 121.2 125 97 121.2 100
IgA (63) S4 C2 0 9424 9355.5 60.98 62.5 98 60.98 100
IgA (63) S4 D2 0 9429.5 9361 61.04 62.5 98 61.04 100
IgA (63) S5 E2 0 6511 6442.5 33.66 31.25 108 33.66 100
IgA (63) S5 F2 0 6438 6369.5 33.12 31.25 106 33.12 100
IgA (63) S6 G2 0 3570.5 3502 15.51 15.63 99 15.51 100
IgA (63) S6 H2 0 3352 3283.5 14.39 15.63 92 14.39 100
IgA (63) S7 A3 0 2134.5 2066 8.54 7.81 109 8.54 100
IgA (63) S7 B3 0 1894.5 1826 7.42 7.81 95 7.42 100
IgA (63) S8 C3 0 1153.5 1085 3.88 3.91 99 3.88 100
IgA (63) S8 D3 1 1083 1014.5 3.91 100
IgA (63) X1 E3 0 2394.5 2326 9752.02 9752.02 100
IgA (63) X1 F3 0 2384.5 2316 9705.1 9705.10 100
IgA (63) X2 G3 0 2961 2892.5 12456.86 12456.86 100
IgA (63) X2 H3 0 2969 2900.5 12495.85 12495.85 100
IgA (63) X3 A4 0 8926.5 8858 55372.4 55372.40 100
IgA (63) X3 B4 0 8739.5 8671 53381.51 53381.51 100
IgA (63) X4 C4 0 7234 7165.5 39341.91 39341.91 100
IgA (63) X4 D4 0 7241 7172.5 39399.93 39399.93 100
IgA (63) X5 E4 0 6085 6016.5 30578.07 30578.07 100
IgA (63) X5 F4 0 6470.5 6402 33358.69 33358.69 100
IgA (63) X6 G4 0 1553.5 1485 5832.05 5832.05 100
IgA (63) X6 H4 0 1548 1479.5 5806.1 5806.10 100
IgA (63) X7 A5 0 4742 4673.5 21949.91 21949.91 100
IgA (63) X7 B5 0 4497 4428.5 20529.56 20529.56 100
IgA (63) X8 C5 0 1912 1843.5 7505.2 7505.20 100
IgA (63) X8 D5 0 1979 1910.5 7816.08 7816.08 100
IgA (63) X9 E5 0 3960 3891.5 17556.35 17556.35 100
IgA (63) X9 F5 0 3995 3926.5 17744.66 17744.66 100
IgA (63) X10 G5 0 13350.5 13282 128812.23 128812.23 100
IgA (63) X10 H5 0 13377.5 13309 129489.39 129489.39 100
IgA (63) X11 A6 0 8396.5 8328 49883.65 49883.65 100
IgA (63) X11 B6 0 7874 7805.5 44909.96 44909.96 100
IgA (63) X12 C6 0 3842 3773.5 16926.81 16926.81 100
IgA (63) X12 D6 0 3862.5 3794 17035.6 17035.60 100
IgA (63) X13 E6 0 6240.5 6172 31681.61 31681.61 100
IgA (63) X13 F6 0 6344 6275.5 32429.56 32429.56 100
IgA (63) X14 G6 0 1548 1479.5 5806.1 5806.10 100
IgA (63) X14 H6 0 1536.5 1468 5751.79 5751.79 100
IgA (63) X15 A7 0 2167 2098.5 8689.31 8689.31 100
IgA (63) X15 B7 0 2065 1996.5 8215.23 8215.23 100
IgA (63) X16 C7 0 5924.5 5856 29463.74 29463.74 100
IgA (63) X16 D7 0 5872.5 5804 29107.95 29107.95 100
IgA (63) X17 E7 0 2659 2590.5 11002.31 11002.31 100
IgA (63) X17 F7 0 2627.5 2559 10852.37 10852.37 100
IgA (63) X18 G7 0 5499 5430.5 26624.77 26624.77 100
IgA (63) X18 H7 0 5365.5 5297 25766.8 25766.80 100
IgA (63) X19 A8 0 7992 7923.5 45997.75 45997.75 100
IgA (63) X19 B8 0 7503 7434.5 41616.31 41616.31 100
IgA (63) X20 C8 0 4303 4234.5 19434.09 19434.09 100
IgA (63) X20 D8 0 4300.5 4232 19420.14 19420.14 100
Sampling Errors: 1 - Low bead #, 2 - Agg beads, 3 - Classify %, 4 - Region selection, 5 - Platform temperature
***Value not available / --- = Designated as an outlier
*Value extrapolated beyond standard range
OOR = Out of Range / OOR> = Out of Range Above  / OOR< = Out of Range Below
Exp Conc = Expected Concentration  /  Obs Conc = Observed  Concentration
Conc in Range = Unknown sample concentrations within range where standards recovery is 70-130%
Regression Type: Logistic - 5PL
Std. Curve: FI = 562.342 + (25617.9 - 562.342) / ((1 + (Conc / 16.2221)^-0.666801))^3.02541
FitProb. = 0.4828, ResVar. = 0.8195